Block ladder reinforcement
Ladder and truss types. BS 4483 · ASTM A951.

Building Materials
Block ladder and truss reinforcement, steel lintels and wall ties that give masonry walls tensile strength.
Overview
Masonry is strong in compression and weak in tension. Block ladder and truss reinforcement give walls tensile strength against wind and seismic loads and reduce cracking.
Strong, lightweight steel lintels, wall ties, dovetails and cavity ties complete the blockwork.
Bed joint reinforcement is laid in the mortar joints at the vertical spacing the design specifies, often every second or third course, and lapped at joints and corners. Lintels are selected by clear span, wall thickness and the load above the opening, and need enough end bearing on each side. Where walls are exposed to moisture or coastal air, galvanised or stainless steel reinforcement and ties resist corrosion in the joints.

Technical data
Every line is matched to your specification. Send your list to sales@alaitimad.com for a quotation within one working day.
| Bed joint reinforcement | Ladder or truss type, width to suit the block. BS EN 845-3 · ASTM A951. |
|---|---|
| Steel lintels | Selected by clear span, wall thickness and load. BS EN 845-2. |
| Wall ties | Tie cavity leaves together, or new walls to columns. BS EN 845-1. |
| Corrosion protection | Galvanised or stainless steel where walls are exposed to moisture or coastal air. |
| For a quotation, send | Block width, wall lengths, the opening schedule with spans and wall thickness, and the specification. |
Range
Block ladder and truss reinforcement, steel lintels and wall ties that give masonry walls tensile strength.
Ladder and truss types. BS 4483 · ASTM A951.
Strong, lightweight lintels. BS EN 845-2.
Wall ties, dovetails and cavity ties. BS EN 845-1.
Distributor

Product images
Select an image to view it larger.


FAQ
Quick answers about Masonry Reinforcement & Lintels. Need more detail? Our team in Yanbu replies within one working day.
Request a quoteReinforcement gives walls tensile strength against wind and seismic loads and reduces cracking.
Steel lintels to BS EN 845-2.
Ladder type has straight cross wires and suits most walls. Truss type has diagonal cross wires, giving stiffer reinforcement for higher lateral loads. The structural design or specification decides which to use.
By the clear span of the opening, the wall thickness and the load above it. Send the opening schedule and we match lintels to it.
Tell us the scope, the timeline and the site. Our team in Yanbu will reply with a tailored proposal within one working day.